espa2
espa
BACK TO PRODUCTS
HAMILTON-T1
MANUFACTURER : HAMILTON MEDICAL AG
Intelligent transport ventilation
  • Approved for use in ambulances, helicopters and airplanes
  • Adult, pediatric, and neonatal ventilation
  • > 9 h of battery operating time
  • Noninvasive ventilation and integrated high flow oxygen therapy
DETAILED DESCRIPTION
TECHNICAL SPECIFICATIONS
ACCESSORIES
RELATED FILES
VIDEO

The HAMILTON-T1 combines for the first time the functionality of a fully featured intensive care unit ventilator with the compactness and ruggedness required for transport. This is why the HAMILTON-T1 enables you to provide optimal ventilation therapy to all patient groups during transport, from the neonate to the adult.

The integrated high-performance turbine enables the HAMILTON-T1 to be completely independent from compressed air. This reduces weight and saves space, and allows even noninvasively ventilated patients to be transported successfully across greater distances.

The HAMILTON-T1 includes Hamilton Medical’s standardized Ventilation Cockpit user interface and the unique intelligent ventilation mode, Adaptive Support Ventilation® (ASV®).

The HAMILTON-Τ1 offers:

  • Performance of a fully featured ICU ventilator
  • Approved for ambulances, helicopters, airplanes, and ships
  • Special edition for military forces
  • Adult, pediatric and neonatal ventilation.
  • Independence from air supply with integrated ultra-quiet turbine (up to 260l/m for adult/pediatric and up to 40l/m for neonates
  • O2 supply either from high or low O2 source
  • Minimum size and weight of less than 7 kg
  • Over 9 hours of battery operating time
  • Intelligent automated ventilation via Adaptive Support Ventilation (ASV)
  • Advanced invasive ventilation modes such as (S)CMV+, SIMV+, PCV+, PSIMV+ & SPONT
  • Synchronized non – invasive ventilation modes such as NIV & NIV-ST (optional)
  • Bilevel ventilation modes such as DuoPAP & APRV (optional)
  • Demand-flow nCPAP & nCPAP-PC ventilation modes (optional)
  • High flow oxygen therapy (optional)
  • Automatic response (leak compensation) to varying leaks and adaption of trigger sensitivity in all modes by IntelliTrig
  • Guaranteed rate ventilation by PSync
  • 4 in, TFT color, backlit, touch screen display
  • Display of more than 50 monitoring parameters
  • Visual representation of ventilator dependency and weaning process, grouped into oxygenation, CO2 elimination, patient activity, via Vent Status
  • Real-time visualization of the lungs with representations of tidal volume, lung compliance, resistance, and patient activity via Dynamic lung
  • Graphic display of target and actual parameters for tidal volume, frequency, pressure, patient activity, and minute ventilation via ASV target graphics
  • Real-time waveforms for Paw, Flow, Volume, Capnograph (optional) & Plethysmograph (optional)
  • Loops P-V, V-Flow, P-Flow, V-CO2 & trends up to 72 hours (optional)
  • Storage and display of up to 1,000 events with date and time via Event log
  • Volumetric mainstream capnography, sidestream capnography (optional)
  • SpO2 measurement (optional)
  • Compatibility of the pressure controlled modes (PCV+, PSIMV+, SPONT) with speaking valves via SpeakVave function (optional)
  • Various interface connections such as USB, RS-232, nurse call(optional), CO2 (optional), SPO2 (optional)
  • Trolley with Humidifier support, cylinder holder (optional)
  • Tubing support arm (optional)
  • Multiple handles for various options (jet, ambulance, or bed rail mount)
  • HAMILTON-T1 carrying unit for bedside transport with O2 cylinder (optional)
  • Night vision function via NVG (optional)
  • Standards: IEC 60601-1, IEC 60601-1-2, ISO 80601-2-12, CAN/CSA-C22.2 No. 60601-1, ES60601-1, EN 794-3, EN 1789 for ambulances, EN 13718-1, RTCA/DO-160G for air transport, MIL-STD-461G control of electromagnetic interference

Breathing circuit sets, single use

  • User-friendly as flow sensor, tube, connectors and expiratory valve set are preassembled
  • Heated (for HAMILTON-H900 humidifier) and nonheated breathing circuit sets
  • Reduced risk of Ventilator Associated Pneumonia (VAP) due to single patient use

CO2 measurement

  • Mainstream and sidestream
  • Reliable measurement
  • Comfortable fit

Expiratory valve sets

  • Specially developed for our ventilators
  • Quickly mountable and easy to use
  • High patient safety

Flow sensors

  • High accuracy of tidal volume due to proximal flow measurement
  • Specially developed and approved for use with Hamilton Medical ventilators
  • Reduced risk of Ventilator Associated Pneumonia (VAP) due to single patient usage

High flow interfaces

  • Extra soft material and comfortable fit
  • Highly flexible tube to reduce the risk of kinking
  • Elastic and flexible, 360°-adjustable headband

nCPAP interfaces for neonates

  • High patient comfort due to soft materials and low noise levels
  • Optimal fit due to the flexible connection and adjustable adapter
  • Masks and bonnets from XXS to XXL

Nebulization

  • Effective dose of delivery
  • Silent operation
  • Small particle size

NIV masks

  • Comfortable positioning due to automatic adjustment of the forehead cushion
  • Four interchangeable elbows for any clinical use
  • Color-coded cord for quick release in emergencies

Oxygen measurement

  • Reliable measurement
  • Maintenance free with paramagnetic sensor
  • For all patient groups