The device and its measurement method
Telemetric home blood pressure measurement involves the patient measuring their blood pressure usually 2–3 times a day for 8–12 weeks. The Tel-O-Graph® GSM automatically sends measurements to the Hypertension Management Software (HMS CS) package, which has proven its worth over many years of surgery use. The measurements can be transferred from HMS CS to the practice management software or hospital information system via GDT or HL-7. The Tel-O-Graph® GSM reduces the number of patient visits required, reduces the workload for the physician and his or her assistants and saves time for the patient.
The product benefits
- Maximum measurement accuracy (BHS A/A grading)
- Safe and simple to operate
- Measurement data is automatically transferred by the integrated GSM module
- Automatic status reports save time and smooth the workflow
The clinical benefits
- Faster, more effective blood pressure control
- Long-term improvement in therapeutic effect
- Improved patient compliance and sense of responsibility
- Treatment can be adjusted with minimum effort on the part of the physician, medical assistants and patient
Device data
- Size (LxWxH) and weight: 152 x 108 x 57 mm, 325 g
- Measurement method: Oscillometric
- Validation: BHS A/A Grading, ISO 81060-2:2009
- Measurement precision:
- Blood pressure: ± 3 mmHg
- Pulse: ±2% or ±3 BPM (whichever value is higher)
- Pressure measurement range:
- Systolic 30-260 mmHg
- Diastolic 30-195 mmHg
- Pulse measurement range: 40-240 BPM (beats per minute)
- Frequency bands: Five Bands UMTS (WCDMA/FDD): 800, 850, 900, 1900 and 2100 MHz
- Quad Band GSM: 850, 900, 1800 and 1900 MHz, GSM, GPRS, EDGE, 3G, HSDPA
- Memory capacity: 15 measurements
- Power supply: Batteries 4 x NiMH or LR6, AA
- Communication: Bluetooth 2.1 + EDR or Infrared
- Regulatory standards: IEC 60601-1:2012, DIN EN 1060-3:2010-3, CE Directive 93/42/EEC Class IIa, ISO 81060-2:2009, R&TTE (99/5/EC), DIN EN ISO 10993-5:2009, RoHS (2011/65/EU) and FCC Part 15b
Device data
- Size (LxWxH) and weight: 152 x 108 x 57 mm, 325 g
- Measurement method: Oscillometric
- Validation: BHS A/A Grading, ISO 81060-2:2009
- Measurement precision:
- Blood pressure: ± 3 mmHg
- Pulse: ±2% or ±3 BPM (whichever value is higher)
- Pressure measurement range:
- Systolic 30-260 mmHg
- Diastolic 30-195 mmHg
- Pulse measurement range: 40-240 BPM (beats per minute)
- Frequency bands: Five Bands UMTS (WCDMA/FDD): 800, 850, 900, 1900 and 2100 MHz
- Quad Band GSM: 850, 900, 1800 and 1900 MHz, GSM, GPRS, EDGE, 3G, HSDPA
- Memory capacity: 15 measurements
- Power supply: Batteries 4 x NiMH or LR6, AA
- Communication: Bluetooth 2.1 + EDR or Infrared
- Regulatory standards: IEC 60601-1:2012, DIN EN 1060-3:2010-3, CE Directive 93/42/EEC Class IIa, ISO 81060-2:2009, R&TTE (99/5/EC), DIN EN ISO 10993-5:2009, RoHS (2011/65/EU) and FCC Part 15b
Accessories
- Tel-O-Graph® short guide
- Batteries
- Tel-O-Graph® cuffs (S-XL)